Top Appliance Repair
    Repaired

    True TR-42SBS-SS-B Refrigerator Alarm and Not Cooling, Leak Repair and Control Board in San Jose

    The freezer was too cold and the fresh side was at 65°F. We found and fixed a refrigerant leak, replaced the main control board and sensors, and recharged the system.

    Repair at a glance

    CitySan Jose, CA
    ApplianceCommercial Refrigerator
    CategoryCommercial
    Brand & modelTrue TR-42SBS-SS-B
    Repair date
    Customer complaintThe break room refrigerator kept sounding an alarm for service and was not cooling properly.
    DiagnosisThe freezer was at -10°F and the refrigerator at +65°F instead of 0°F and 37°F. The temperature control board was not working properly, and there was a refrigerant leak on the refrigerator side.
    Repair cost$2,993
    Warranty6 months on parts and labor
    OutcomeRepaired

    What the customer told us

    The True refrigerator in the first-floor break room kept alarming for service and the fresh side was not cooling.

    What we found

    The freezer read -10°F and the refrigerator +65°F. We found two problems: the temperature control board was not working correctly, and there was a refrigerant leak on the refrigerator side.

    How we repaired it

    We pulled the unit out, located and repaired the leak, replaced the filter drier, pressure checked the sealed system, pulled a vacuum and recharged it. We also installed a new main control board and sensor kit, then put the unit back in place.

    Testing

    We checked pressures with the gauges and watched both sides come down to temperature.

    Photos from this repair

    • True TR-42SBS-SS-B: True TR-42SBS-SS-B in the break room
      True TR-42SBS-SS-B in the break room.
    • True TR-42SBS-SS-B: Display showing the temperatures before the repair
      Display showing the temperatures before the repair.
    • True TR-42SBS-SS-B: True data plate
      True data plate.
    • True TR-42SBS-SS-B: Unit pulled out with gauges connected
      Unit pulled out with gauges connected.
    • True TR-42SBS-SS-B: Evaporator inside the refrigerator side
      Evaporator inside the refrigerator side.
    • True TR-42SBS-SS-B: Control wiring at the top of the unit
      Control wiring at the top of the unit.
    • True TR-42SBS-SS-B: Control board area up close
      Control board area up close.
    • True TR-42SBS-SS-B: Leak search with the gauges connected
      Leak search with the gauges connected.
    • True TR-42SBS-SS-B: Gauge readings during the charge
      Gauge readings during the charge.
    • True TR-42SBS-SS-B: Refrigerator back in place after the repair
      Refrigerator back in place after the repair.

    Need True commercial refrigerator repair?

    $85 diagnostic applied to the repair. Serving San Jose, San Francisco & the Bay Area.