Repaired
Trenton Walk-In Freezer Stopped Working, Head Pressure Control Replaced in San Jose
The walk-in freezer had stopped because the head pressure control failed. We recovered the refrigerant, replaced the control, drier, solenoid valve and fan impeller, then vacuumed, tested and recharged the system.
Repair at a glance
| City | San Jose, CA |
|---|---|
| Appliance | Walk-In Freezer |
| Category | Commercial |
| Brand & model | Trenton TEZA010L6-HT3D-F |
| Repair date | |
| Customer complaint | The walk-in freezer stopped working. |
| Diagnosis | The adjustable head pressure control was not working and needed to be replaced. Because it is part of the sealed system, the refrigerant had to be recovered, the part replaced, the system vacuumed, leak tested, recharged and adjusted. |
| Repair cost | $1,631 |
| Warranty | 6 months on parts and labor |
| Outcome | Repaired |
What the customer told us
The walk-in freezer had stopped working.
What we found
On the rooftop condensing unit the adjustable head pressure control was not working.
How we repaired it
We recovered the R-404A, replaced the head pressure control, the filter drier and the solenoid valve, and replaced the condenser fan impeller. Then we ran a high-pressure test, pulled a vacuum, charged the system and adjusted it. The work took a full day.
Testing
The condensing unit started and the freezer pulled down.
Photos from this repair

Rooftop condensing unit. 
Condensing unit data plate. 
Evaporator unit data plate inside the freezer. 
Condenser coil. 
Piping inside the condensing unit. 
Valve on the refrigerant line. 
Solenoid valve on the liquid line. 
Valve in the line set. 
New head pressure control installed. 
Tools and parts set up on the roof.
Need Trenton walk-in freezer repair?
$85 diagnostic applied to the repair. Serving San Jose, San Francisco & the Bay Area.