    Sub-Zero 680/S Refrigerator Not Cooling: Sealed System Rebuilt in Foster City

    A Sub-Zero 680/S built in 2000 lost cooling in the refrigerator section because of a refrigerant leak. We replaced almost the whole sealed system except the condenser coil, pulled a long vacuum and recharged it.

    Repair at a glance

    CityFoster City, CA
    ApplianceRefrigerator
    CategoryHigh-End Brands
    Brand & modelSub-Zero 680/S built-in side-by-side, serial P1652807 (made August 2000, R134a)
    Repair date
    Customer complaintThe refrigerator section was slowly getting warmer and food had started to spoil. Another company had worked on it about a year earlier, but the problem came back.
    DiagnosisVery low suction pressure on the refrigerator sealed system, which points to a refrigerant leak. The display showed 45°F in the fresh-food section.
    Repair cost$3,485 (parts and labor)
    Warranty1 year on all work
    OutcomeRepaired

    What the customer told us

    The customer said the refrigerator section of her Sub-Zero was not cooling well. Someone had worked on it about a year before, but over time the temperature crept up again, and recently food began to spoil.

    Diagnosis: a refrigerant leak

    The rating label shows a Sub-Zero 680/S, serial P1652807, made in August 2000 and running on R134a. During the diagnostic visit the control showed 45°F in the refrigerator section.

    We connected gauges and found very low suction pressure. That means refrigerant is escaping somewhere in the sealed system.

    What we replaced

    Since the leak could be in several old components, the customer approved replacing almost the entire refrigerator sealed system except the condenser coil: the compressor, the evaporator, the capillary tube line set, the drain loop and the filter drier.

    All parts were genuine Sub-Zero parts bought from the Sub-Zero distributor in San Leandro. After the quote was approved we ordered the parts, and the whole job took about three days.

    How the repair is done

    The refrigerator has to be pulled completely out of its opening. We removed the top cover and vacuumed the dust out of the machine compartment.

    Inside, we took apart the refrigerator section to reach the evaporator: the ice maker parts, shelf rails, covers, protective panels and the drain heater all come out. Sub-Zero now sells the evaporator with the drain pan and heater already assembled, which made this step easier.

    The new capillary tube line set is fed up to the top of the unit, connected to the new compressor and brazed in, together with the new filter drier.

    Vacuum and refrigerant charge

    Before charging, we ran a long evacuation to remove air and moisture from the system. The vacuum gauge reached about 735 microns, as shown in the photos.

    Then we charged the system with R134a and checked operation on the gauges.

    Result

    After the repair the refrigerator section cools again and the unit has kept running since. The total for this job, including all parts and labor, was $3,485. Sealed-system repairs like this come with a 1-year warranty on all work.

    Photos from this repair

    • Sub-Zero 680/S built-in side-by-side refrigerator in a kitchen
      The Sub-Zero 680/S before the repair.
    • Sub-Zero control display showing 45°F in the refrigerator section
      The refrigerator section reading 45°F at diagnosis.
    • Technician working on the open Sub-Zero machine compartment
      Unit pulled out, machine compartment open.
    • Sub-Zero compressor, filter driers and tubing in the machine compartment
      Taking apart the old sealed-system parts.
    • Old Sub-Zero compressor DA73C12RCU6 R134a after removal
      The old compressor after removal.
    • New Sub-Zero evaporator with drain pan and heater in its box
      New evaporator with drain pan and heater pre-assembled.
    • Sub-Zero refrigerator section emptied with the evaporator removed
      Refrigerator section stripped to reach the evaporator.
    • New evaporator installed next to the Sub-Zero 680/S rating label
      New evaporator installed; rating label shows 680/S, serial P1652807.
    • Technician feeding the line set up through the Sub-Zero cabinet
      Feeding the new line set to the top of the unit.
    • Insulated capillary line set running up to the Sub-Zero compressor
      New line set routed up to the compressor.
    • Evaporator and insulated line set on the kitchen counter
      Evaporator and line set on the counter.
    • Sub-Zero drain loop tube laid out on a countertop
      The drain loop.
    • Vacuum pump, refrigerant cylinder and tools next to the Sub-Zero
      Vacuum pump, refrigerant and tools set up.
    • Testo digital manifold during evacuation of the Sub-Zero system
      Evacuation in progress on the digital manifold.
    • Testo app showing the vacuum at 735 microns
      Vacuum down to about 735 microns.
    • Digital manifold connected to the Sub-Zero after charging
      System charged and checked on the gauges.