Nor-Lake Walk-In Cooler Condensing Unit Replacement in San Jose
The walk-in at a sushi restaurant was warming up because the compressor had shorted out. We replaced the condensing unit, the evaporator coil and the defrost timer, then charged and started the system.
Repair at a glance
| City | San Jose, CA |
|---|---|
| Appliance | Walk-In Cooler |
| Category | Commercial |
| Brand & model | Nor-Lake RRT64C1E-IAA-959 |
| Repair date | |
| Customer complaint | The walk-in cooler temperature was too high. |
| Diagnosis | The compressor had a short circuit and no longer worked. The condensing unit assembly needed to be replaced. |
| Repair cost | $3,701 |
| Warranty | 6 months on parts and labor |
| Outcome | Repaired |
What the customer told us
The restaurant called because the temperature in their Nor-Lake walk-in cooler was climbing too high.
What we found
We opened the condensing unit on top of the box. The compressor had a short circuit in the windings and would not run, so the box had no cooling at all. The old unit had a Copeland compressor, and the coil and base showed years of dirt and corrosion.
How we repaired it
We offered two options: a compressor only, or a complete condensing unit. The customer chose the full assembly. We recovered the system, removed the old condensing unit, set the new 6,760 BTU unit (RRT64C1E-IAA-959) on the roof of the box and brazed in the suction and liquid lines. The evaporator coil inside the box was replaced as well, along with the defrost timer.
Testing
After a pressure test and vacuum we charged the system and started it up. We checked pressures, the fan motors and the defrost timer, and watched the box temperature come down.
Photos from this repair

Kitchen of the restaurant with the walk-in cooler. 
Nor-Lake walk-in cooler panel. 
Old condensing unit with the housing open. 
Old condenser coil. 
Shorted compressor in the old condensing unit. 
Old condensing unit on top of the walk-in. 
Condensing unit area during the replacement. 
Condenser and drier during the swap. 
Liquid line drier on the new unit. 
Empty base after the old unit was removed. 
New condensing unit set in place. 
New unit with gauges connected. 
New condensing unit connected on top of the box. 
New unit after the lines were brazed. 
Compressor and lines on the new condensing unit. 
Finished installation on top of the walk-in cooler.