GE GUD27EESN Laundry Center Dryer Not Drying: Control Board, Thermostat and Exhaust Cap in East Palo Alto

A GE GUD27EESN laundry center would not dry even after vent cleaning. We found a failed control board and thermostat inside the dryer, and a grille on the outside vent outlet that would keep clogging. Both were repaired.

Repair at a glance

CityEast Palo Alto, CA
ApplianceStacked Laundry Set
CategoryMajor Brands
Brand & modelGE GUD27EESN0WW
Repair date
Customer complaintSeveral people had checked this stacked GE dryer and found nothing wrong, but it still would not dry, even after the vents were cleaned. The customer suspected a fuse.
DiagnosisThe vent run was in good condition, but a louvered grille at the outlet was the wrong type and would clog. The dryer control board and thermostat also needed to be replaced.
Repair cost$821
Warranty6 months on parts and labor
OutcomeRepaired

What the customer told us

The customer had already had four or five people look at this stacked GE washer-dryer, and the vents had been cleaned, but the dryer still would not dry. They thought a fuse might be the problem.

What we found

We started with the vent. The duct behind the unit and the run to the outside wall were in good condition, but the wall outlet had a small louvered grille. That type of grille restricts airflow and clogs with lint over time, so we recommended a proper round dryer exhaust cap.

Inside the dryer, we removed the rear and control panels to reach the heater, thermostats and control board. Testing confirmed that the dryer control board and a thermostat had failed, which explained why the dryer ran but did not dry.

How we repaired it

We pulled the laundry center out of the closet, opened the dryer section and installed a new thermostat on the heater housing. In the control panel, the old board was disconnected and the new control board was installed with each harness plugged back into place.

On the outside wall, the old grille was removed and a dedicated dryer exhaust cap was installed.

Testing

After reassembly, we ran the dryer on heat, confirmed it was heating and that air was exhausting freely through the new cap.

Photos from this repair

  • GE GUD27EESN stacked laundry center dryer drum
    The stacked GE laundry center.
  • GE laundry center pulled out of closet
    Unit pulled out of the closet for access.
  • GE laundry center with dryer section opened
    Dryer section opened in the hallway.
  • GE dryer heater and drum seen from the rear
    Rear view of the heater and drum.
  • GE dryer thermostat on heater housing
    Thermostat on the heater housing.
  • GE dryer heater coil housing
    Heater coil inside its housing.
  • GE laundry center dryer interior
    Dryer interior with the panels removed.
  • New thermostat installed on GE dryer
    New thermostat in place.
  • GE dryer motor and wiring
    Motor and wiring at the base of the dryer.
  • GE dryer heater housing and terminals
    Heater housing and terminals.
  • GE dryer control board in control panel
    Control board inside the control panel.
  • Old GE dryer control board wiring
    Old control board with its harnesses.
  • GE dryer control board close-up
    Control board relays and connectors.
  • New GE dryer control board installed
    New control board installed.
  • GE dryer control board harnesses reconnected
    Harnesses reconnected to the new board.
  • GE dryer control panel opened
    Control panel opened during the repair.
  • GE laundry center control panel reassembled
    Control panel after reassembly.
  • Louvered grille on dryer vent outlet
    The louvered grille that was on the wall outlet.
  • GE dryer vent duct behind the unit
    Vent duct behind the unit.
  • New dryer exhaust cap on exterior wall
    New dryer exhaust cap installed on the wall.